Page 81 - TIS Catalog
P. 81

PANEL ADDITION ~ RELAYS













                   Panel Addition 2 Digital Inputs with Infrared Emitter  Panel Addition 2 Digital Inputs with Infrared Receiver  Panel Addition 3 Digital Inputs with 12V Power Supply
                            Number of Channels  2                          Number of Channels  2                          Number of Channels  3
                      INPUT  Input Type   Digital Input. Open / Close      Input Type   Digital Input. Open / Close  INPUT  Input Type   Digital Input. Open / Close
                                                                     INPUT
                            Length of Connected Cable  < 350 meter         Length of DI Connected Cable  < 350 Meters     Length of Connected Cable  < 350 Meter
                                                                           IR Receiver Connected Cable   Length < 5 Meters
                            IR Emitter Peak Wave Length  940 nm                                                     OUTPUT  Low Voltage    12VDC 100mA
                     OUTPUT  Radiated Emission Power (Φe)  2,4 mW          Digital Input Open  20 Commands
                                                                                                                          Digital Input Open  20 Commands
                            Length of Connected Cable  < 5 meters   FUNCTIONS  Digital Input Close  20 Commands
                                                                                                                   FUNCTIONS  Digital Input Close  20 Commands
                                                                           Revers Control  1 Command
                                         Attach to the Back of TIS Panels                                                 Revers Control  1 Command
                     MOUNTING   Behind the Panel  Including Luna, IO, Mars, Terre-A     Attach to the Back of TIS Panels
                                         Fits Into All Standard Back Boxes
                                                                    MOUNTING   Behind the Panel  Including Luna, IO, Mars, Terre-A      Attach to the Back of TIS Panels
                                                                                        Fits Into All Standard Back Boxes  MOUNTING   Behind the Panel  Including Luna, IO, Mars, Terre-A
                                                                                                                                        Fits Into All Standard Back Boxes








                   Panel Addition Three-Channel Coupler           ADS RELAY SWITCH Controller Module with Three Relays  Power Relay 6 Channels 5 Amps
                                        For Incandescent Lamps (200                       10A / 230VAC Resistive            Number of Channels  6
                            3 Separate Channels                               Max Switching Current
                                        Watts)                                            6A / 230VAC florescent
                                                                   OUTPUT SWITCHING                                         Nominal Voltage  0 – 230VAC 50/60 Hz
                            Simple FCU Function  Cool, Heat, Fan Outputs  CURRENT  Max Continues Current    8A / 230VAC
                                                                                                                            Nominal Current per Channel
                     FUNCTIONS  Fan Speed Control  Low, Medium, High Outputs  Max. Switching Voltage  277VAC / 30VDC
                                                                                                                    OUTPUT  Low Current  5A
                                        Ch1 & Ch2 as Open / Close
                                                                                                                            Lighting Incandescent Lamp  4A
                            Motor and Lighting  Interlocked, Ch3 to Work      Number of Relays  3
                                        Independently                                                                       Motors / Air Condition  3A
                                                                      OUTPUT  Nominal Voltage  0-230VAC 50/60 Hz
                                                                                                                            LED and CFL Lamp  1A
                                                                              Nominal Current per Channel 8A / 230VAC
                            Number of Channels  3
                            Nominal Voltage  0–230VAC 50/60 Hz                                                                           6 Separately Controllable
                                                                      MOUNTING   Free Locate  Can be Installed Anywhere     Lighting Control ON/OFF
                                                                                                                                         Channels
                            Low Current  5A / 28VDC
                      OUTPUT                                                                                                             Can Set 3 Groups of Curtains
                            Lighting Incandescent Lamp  4A / 230VAC    OUTPUT SERVICE LIFE Mechanical Endurance  > 10,000,000 OPS  FUNCTION  Motor Setting
                                                                                                                                         (Open/Close)
                            Motors / Air conditioning  3A / 230VAC                                                                       Can Set 2 Groups of Fans
                                                                                                                            Fan Speed Control
                            LED and CFL Lamp  1A / 230VAC                                                                                (Low, Med, High)
                                        Attach to the Back of TIS Panels                                         OUTPUT SERVICE LIFE Mechanical Service Life  > 5,000,000 Times
                     MOUNTING   Behind the Panel  Including Luna, IO, Mars, Terre-A
                                        Fits Into All Standard Back Boxes
                                                                                                                            Din Rail     Standard 35 mm Din Rail
                                                                                                                    MOUNTING             Screw Holder on the Back of
                                                                                                                            Wall Mount
                                                                                                                                         the Module
                                                                                                                                                      PA G E
                                                                                                                                                      79