Page 88 - TIS Catalog
P. 88

METERS


















                 KNX Standard Communicator                       Smart Water Meter                              Weather Station
                          KNX       KNX Network 2 Wires Connection        Bus Pin ESD Protection   Exceeds 10kV            Range      -30˚C - 60˚C
                    INPUT                                         PROTECTION                                     TEMP. MEASURING
                          TIS       TIS-BUS (RS485) 4 Wires Connection                    Open Circuit, Short Circuit      Accuracy   +/- 1°C
                                                                          Protection Against Faults
                                                                                          and Idle BUS
                          TIS->KNX  Control Lights ON/OFF, Dimmer and Shutter                                              Range      10%~99%
                                                                                                                HUMIDITY MEASURING
                   FUNCTION         Control Lights ON/OFF, Dimmer, Shutter,   Communication With Host Computer  RS-485, M-BUS, Fieldbus  Accuracy   +/- 5%
                          KNX->TIS
                                    Infrared and Air Condition            Communication Transmission Rate  2400 BPS
                                                                 COMMUNICATION                                             Range      0 – 9999mm
                                                                          Communication Transmission Max.       RAIN VOLUME DISPLAY
                 REACTION TIME      Approx. 40ms                                          1200m                            Accuracy   +/- 10%
                                                                          Distance
                   MOUNTING   Din Rail   Standard 35 mm Din Rail                                                           Range      0-50m/s (0~100mph)
                                                                                          165mm × 90mm × 120mm    WIND SPEED
                                                                                          (DN 15mm)                        Accuracy   +/- 1m/s (Wind Speed< 5m/s)
                                                                                          195mm × 90mm × 120mm
                                                                 DIMENSTIONS  Length × Width × Height                      Range      0-400000 Lux
                                                                                          (DN 20mm)
                                                                                                                  BRIGHTNESS
                                                                                                                           Accuracy   +/- 15%
                                                                                          225mm × 90mm × 120mm
                                                                                          (DN 25mm)
                                                                                                                   MOUNTING     Outdoors  Special Tool for Roof Installation
                 Modular Single-Phase Power Meter               Modular Three-Phase Power Meter                 Six Valve Controller
                            Voltage AC (Un)   176-276VAC / 80-140VAC (optional)    Phase to neutral   100 to 289V a.c. (not for 3p3w supplies)  Number of Channels  6
                            Base Current (Ib)   10A                    voltages                                    OUTPUT   Nominal Voltage  24 VAC 50/60 Hz
                            Max. Current (Imax)   100A                 Voltages between
                     INPUT                                             phases   173 to 500V a.c. (3p supplies only)
                            Min. Current (Imin)   0.5 A                                                            INPUT    6× Temp. Inputs  TIS Temp. Sensor
                                                                VOLTAGE AND
                            Power Consumption   <2W / 10VA       CURRENT  Percentage total   (THD%) for each phase to N ( not for 3p3w
                                                                       voltage harmonic
                            Frequency   50/60Hz(±10%)                           supplies)                       OUTPUT SERVICE LIFE  Mechanical Service   >5,000,000 Times
                                                                       distortion
                                                                                                                            Life
                                                                       Percentage voltage   THD% between phases (three phase supplies only)
                            LCD       LCD with Blue Backlit
                     DISPLAY                                           Current   THD% for each phase             REACTION TIME       Approx. 20ms
                            Max. Reading   99999.99kWh
                   REACTION TIME      Approx. 20ms                     LCD      LCD with Backlit                  MOUNTING   Din Rail   Standard 35 mm Din Rail
                                                                 DISPLAY                                                    Wall Mount  Screw Holder on the Back of the Module
                                                                       Max. Reading   0 to 9999999.9 kWh
                    MOUNTING   Din Rail    Standard 35 mm Din Rail
            PA G E                                             ENVIRONMENT  Relative humidity  0 to 95%, noncondensing
           86                                                   MOUNTING   Din Rail    Standard 35 mm Din Rail
   83   84   85   86   87   88   89   90   91   92   93